1Step RT qPCR Probe ROX L Kit

Applications

  • SARS-CoV-2 detection by RT qPCR, COVID-19 assays.
  • RT-qPCR assays based on specific probes, such as TaqMan®, Molecular Beacons, Scorpions™ Probes.
  • Gene expression analysis, quantification of gDNA, cDNA, viral DNA, low copy number genes.

Benefits

  • Efficient Reverse transcription and sensitive qPCR in one tube
  • Both standard or fast cycling, GC rich templates.
  • Rapid extension, early Ct.

€224.50*

Product sizes
200 reactions of 20 µl
€224.50*
1000 reactions of 20 µl
€974.50*

↑ Collapse variants ↑

Selected Catalog #: QOP0201
Product information "1Step RT qPCR Probe ROX L Kit"
highQu 1Step RT qPCR master mixes in combination with a blend of thermostable and extremely active Reverse Transcriptase & advanced RNase Inhibitor (RT Mix) allow for a single step one tube RT qPCR.
qPCR master mixes are based on the small molecular inhibitor technology Hot Start PCR allowing to achieve highest sensitivity and specificity under both standard and fast qPCR cycling conditions. They provide excellent results on both AT/GC rich templates and guaranty rapid extension with early Ct values with minimum or no optimization.
Our master mixes are supplied with PCR Water to guaranty the best performance. To suit the broad instrument range the 1Step RT qPCR Probe Mixes are available in three versions – without ROX, with low or high ROX concentration.

Related Products

PCRbeam™ Fast PCR Detection Kit
highQu PCRbeam™ Fast PCR Detection Kit is a convenient tool for fast detection of gene-specific amplification products obtained by PCR, LAMP or RPA. The detection is based on immunological reaction driven by Biotin and FITC (fluorescein isothiocyanate), thus the amplified DNA shall include Biotin and FITC labels. The PCR amplification has to be performed with one primer labeled with FITC at 5’-end and one primer labeled with Biotin at 5’-end. Alternatively the use of one of the labeled primers can be replaced by gene-specific FITC or Biotin labeled probe. Kit includes PCRbeam™ Membrane Strips that are coated with biotin-ligand on the test band and an anti-rabbit antibody on the control band. The bottom part of the strip which is used for sample application contains an anti-FITC antibody attached to gold particles. PCRbeam™ Detection Buffer is Tris-buffered saline enabling the detection. The PCRbeam™ Fast PCR Detection Kit can be applied for established tests or home-brew assays as a fast and sensitive yes/no detection method. The detection sensitivity is up to 100 fold higher than the one achievable with ethidium bromide stained gels what provides an environment friendly save and economical alternative to the use of mutagen stains. For establishing sensitive PCR-based tests before PCRbeam™ detection we recommend the use of hot-start PCR enzymes or master mixes, like highQu ALLin™ Hot Start Taq Mastermix or ALLin™ Hot Start Taq DNA Polymerase. Principle: The membrane strip is soaked for 10 minutes into the vial with the detection buffer mixed with PCR product. The lateral sample flow driven by gold particles moves the solution up the strip. FITC labeled DNA strand binds with the anti-FITC antibody on the gold particle and Biotin labeled DNA strand is caught by Biotin ligand attached to the test band. As both DNA strands remain hybridized at room temperature, the test band builds an aggregate that develops red-blue color. Excess gold particles that were not caught by FITC move up the strip and the anti-FITC antibody binds to the anti-rabbit antibody to develop the red-blue colored control band. If there is no PCR product in the reaction, then only the control band will be visible. If there is a specific product, the test band will be colored as well.

€119.50*
ORA™ qPCR HRM Mix
High Resolution Melting analysis (HRM) is a fast and simple technique for identification of DNA sequence variations. It allows identifying single nucleotide differences by detecting minor changes in qPCR melting curves. highQu ORA™ HRM qPCR Mix includes a proprietary intercalating saturating dye showing no inhibition for PCR. The dye has the same affinity for both AT or GC rich sequences what leads to highest accuracy in genotyping. The hot-start function in the mix is based on the small molecular inhibitor technology and allows achieving highest sensitivity and specificity under both standard and fast qPCR cycling conditions. The mix provides excellent performance on both AT and GC rich templates and reliable results with minimum or no optimization. Our master mixes are supplied with PCR Water to guaranty the best performance.

€117.50*
ALLin™ Mega HiFi DNA Polymerase
Derived from our HiFi polymerase, the highQu ALLin™ Mega HiFi DNA Polymerase provides much lower error rate PCR with a 100 higher fidelity compared to Taq. The ALLin™ Mega HiFi DNA Polymerase is engineered to be much faster and to generate a higher yield of long PCR products up to 20 kb from complex GC-rich templates. Therefore the ALLin™ Mega HiFi DNA Polymerase is an excellent choice for longer and very complex PCR applications where the highest fidelity is demanded. It is an enzyme of choice for cloning and all kind of sequencing applications including NGS. Generated blunt-ended PCR products are suitable for ligation into blunt vectors.  For maximum convenience, the ALLin™ Mega HiFi Mastermix, 2X (HLM0201) and ALLin™ Mega HiFi Red Mastermix, 2X (HLM0301) are available.

€99.50*
StainIN™ GREEN Nucleic Acid Stain
StainIN™ GREEN Nucleic Acid Stain is a significantly safer alternative to ethidium bromide. It is same easy to use, 4X as sensitive (under Blue LED) and much more secure. More economical as other green dyes, this stain can be also used and disposed with less environmental and health concerns compared to ethidium bromide. It is a fluorescent dye that allows detection of >0,1 ng of DNA in both agarose and polyacrylamide gels. It binds to both dsDNA, ssDNA and RNA and emits green fluorescence when bound to DNA and red fluorescence when bound to RNA detectable under the UV or Blue light and documented with same filters as similar green dyes. StainIN™ GREEN is ideal for DNA extraction from gels for cloning. Smaller than ethidium bromide carcinogenicity has been proved by Ames-test. Mammalian cell mutagenicity tests, both mouse marrow erythrocyte micronucleus and spermatocyte chromosomal aberration tests gave negative mutagenicity results.

€98.00*