ORA™ qPCR Green ROX L Mix, 2X

Applications


  • Dye based qPCR on instruments calibrated with low ROX concentration

  • qPCR from gDNA, cDNA, viral DNA, low copy number genes

  • Relative gene expression analysis, absolute quantification

Benefits

Catalog. # Product Name Size Price Qty
QPD0101 ORA™ qPCR Green ROX L Mix, 2X 200 r of 20 µl
€117.50
QPD0105 ORA™ qPCR Green ROX L Mix, 2X 1000 r of 20 µl
€529.50

Request a Sample.

Description

highQu qPCR mastermixes are based on the small molecular inhibitor technology Hot Start PCR allowing to achieve highest sensitivity and specificity under both standard and fast qPCR cycling conditions. They provide excellent results on both AT and GC rich templates and guaranty rapid extension with early Ct values with minimum or no optimization.

Our mastermixes are supplied with PCR Water to guaranty the best performance. To suit the broad instrument range the ORA™ qPCR Green Mastermixes are available in different versions –with low or high ROX concentration.


For optional use, the ROX passive reference dye is premixed within the ROX L and ROX H qPCR Mixes. If the purchaser has an instrument capable of optional ROX detection and wishes to perform the optional normalization of the signal, then the user must select the option in the software.

Notice to Purchaser: With purchasing of this product, no rights are conveyed with respect to U.S. Patent: 5,928,907 and corresponding patents outside the US.

Protocols

Print version of the protocol: Product Insert ORA™ qPCR Green ROX L Mix, 2X
Important Notes
  • Use special primer selection programs for good planning.
  • Work with amplicons in a range of 80-200, max 400 bp.
  • Take typical measures to prevent PCR cross over contamination, keep your bench clean, wear gloves, use sterile tubes and filter pipet tips.
  • Run reactions in triplets; include a no-template control and positive control in parallel.
  • Thaw and keep reagents on ice. Mix well before use.

 

Prepare a 20 µl reaction:

 

Reverse Primer 100 - 400 nM final c.
Forward Primer 100 - 400 nM final c.
cDNA Template or
gDNA Template
<100ng  or
<1 μg
PCR Water to 10 μl
ORA™ qPCR Mix, 2X 10 μl

 

  • Mix gently, avoid bubbles.
  • Place into the instrument (SYBR® Green or FAM channel), set like:

 

Initial denaturation 1 cycle: 95°C - 2 min for cDNA, or
1 cycle: 95°C - 3 min for gDNA
Denaturation 40 cycles: 95°C - 5 sec
Annealing/extension 40 cycles: 60-65°C - 20-30 sec

 

  • Follow instrument instructions for melt curve analysis.

Specifications

CAT.

SIZE

COMPONENTS

COMPOSITION

QPD0101 200 r
of 20 µl
2 x 1 ml - ORA™ qPCR Green ROX L Mix, 2X
2 x 1 ml - PCR Water
Hot Start qPCR components: dNTPs at 0.25 mM, optimized buffer, low ROX concentration.
QPD0105 1000 r
of 20 µl
10 x 1 ml - ORA™ qPCR Green ROX L Mix, 2X
10 x 1 ml - PCR Water
Hot Start qPCR components: dNTPs at 0.25 mM, optimized buffer, low ROX concentration.


Storage


In the dark at -20°C.