ALLin™ Taq DNA Polymerase, 5 u/µl

Applications


  • Routine PCR up to 6 kb

  • PCR of GC rich templates

  • Colony PCR, Fast PCR, TA cloning

Benefits


  • Higher yields under standard and fast cycling

  • Increased success in amplification of longer (6 kb) and GC rich templates

  • 5X ALLin™ PCR Buffer contains optimal Mg2+ and dNTP concentrations

Catalog. # Product Name Size Price Qty
PCE0101 ALLin™ Taq DNA Polymerase, 5 u/µl 500 u
€159.50
PCE0105 ALLin™ Taq DNA Polymerase, 5 u/µl 2500 u
€719.50

Request a Sample.

Description

highQu ALLin™ Taq DNA Polymerase is the versatile engineered enzyme which in combination with the optimized ALLin™ buffer provides higher success rates in  demanding PCR applications like amplification of complex templates, crude sample PCR and fast cycling. ALLin™ Taq DNA Polymerase has the same PCR accuracy like Taq DNA Polymerase, 4.5 x 104 (a number of correct nucleotides incorporated before the first error). ALLin™ Taq DNA Polymerase produces A-tailed products suitable for ligating into TA cloning vectors. For the maximum convenience the ALLin™ Taq Mastermix, 2X is available.

Protocols

Print version of the protocol: Product Insert ALLin™ Taq DNA Polymerase, 5 u/µl
Important Notes
  • Take typical measures to prevent PCR cross over contamination, keep your bench clean, wear gloves, use sterile tubes and filter pipet tips.
  • Include a no-template control and positive control in parallel.
  • Thaw and keep reagents on ice. Mix well before use.
  • The longer the amplicon, the longer the extension time: 15 sec/kb - <6kb and 1 sec/kb - <1kb. Use >90 sec extension for multiplexing
  • Run an annealing temperature gradient from 55°C to 65°C to choose the best specificity conditions.
  • Do not use fast cycling for multiplexing.
 
Prepare a 50 µl PCR reaction

 

Rev. & For. Primers variable, up to 0.4 µM final each (2 µl of 10 µM each)
cDNA Template  or
gDNA Template
<100 ng   or
5 - 500 ng
5X ALLin™ PCR Buffer 10 μl
Water to 49 μl
ALLin™ Taq DNA Polymerase, 5u/μl
0.25 - 1 µl

 

  • Mix gently, avoid bubbles.
  • Place into the instrument set like:

 

Initial denaturation 1 cycle: 95°C - 1 min
Denaturation 40 cycles: 95°C - 15 sec
Annealing 40 cycles: 55-65°C – 15 sec
Extension 40 cycles: 72°C – 1- 90 sec (15 sec/kb)

 

  • After the PCR store probes on ice shortly, store at -20°C for long term.

Specifications

Cat. Size Components Composition

PCE0101

500 u

500 u - ALLin™ Taq DNA Polymerase, 5 u/µl
4 x 1 ml - 5X ALLin™ PCR Buffer
Enzyme in storage buffer.
1X ALLin™ PCR Buffer contains 0.25 mM dNTPs, 3 mM MgCl2, enhancers, stabilizers.

PCE0105

2500 u

5 x 500 u - ALLin™ Taq DNA Polymerase, 5 u/µl
20 x 1 ml - 5X ALLin™ PCR Buffer
Enzyme in storage buffer.
1X ALLin™ PCR Buffer contains 0.25 mM dNTPs, 3 mM MgCl2, enhancers, stabilizers.

Storage

   In the dark at -20°C.